
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
1 Hazardous Materials Laboratory, California Department of Toxic Substances Control, Berkeley, CA; 2 Environmental Health Investigations Branch, California Department of Health Services, Oakland, CA; 3 Public Health Institute, Oakland, CA; and 4 Department of Surgery, Stanford University School of Medicine, Stanford, CA
Requests for reprints: Myrto Petreas, Hazardous Materials Laboratory, California Department of Toxic Substances Control, 700 Heinz Ave., Suite 100 Berkeley, CA 94710. Phone: (510) 540-3624; Fax: (510) 540-2305. E-mail: mpetreas{at}dtsc.ca.gov
| Abstract |
|---|
|
|
|---|
| Introduction |
|---|
|
|
|---|
Many of these contaminants are considered toxic and have been associated with adverse health effects. Several studies on the possible role of estrogenic or antiestrogenic chemicals in the development of breast cancer have assessed exposures to certain organochlorine compounds through the analysis of biological specimens. In each study, researchers selected a particular type of specimen such as adipose (922), serum (2335), or plasma (3639) that best fit their objectives within constraints of availability and convenience. As these studies resulted in conflicting conclusions, however, it is compelling to explore the possible role of certain laboratory approaches in the apparent discrepancies. In addition to the selected analytical methodologies that may affect precision and accuracy in the measurement of target analytes, auxiliary measurements of lipids and use of such measurements to adjust chemical concentrations may introduce bias in the results.
Blood is much easier to collect than adipose; serum and plasma specimens have been used to assess exposures to lipophilic chemicals in many breast cancer studies (2339). However, while measurements in adipose tissues reflect steady-state concentrations of lipophilic chemicals, measurements in whole blood, serum, and plasma may fluctuate with surges in blood lipids and, as such, may be biased. The main contributor to this bias is the transport mechanism and partitioning of each chemical in the various blood components according to its relative solubility. For example, <18% of dichlorodiphenyldichloroethylene (DDE) or dichlorodiphenyltrichloroethane (DDT), but over 40% of dieldrin, are distributed in the erythrocytes reflecting differences in cell membrane permeability (40). Similarly, most PCDD/PCDF congeners are found in the lipoprotein fraction of blood. The more highly chlorinated congeners (penta- through octa-substituted), however, do not appear to partition between the lipoprotein and the protein fractions according to the lipid content of these fractions (41). Instead, the percentage associated with the protein fraction increases with the degree of chlorination, possibly suggesting preferential binding (41). The adipose/serum partition coefficient is the ratio of the concentration of a chemical in adipose and in serum at equilibrium and determines the degree at which a chemical accumulates in fatty tissues. Because of interindividual and even intraindividual differences in absorption, distribution, metabolism, and elimination of contaminants, empirically derived adipose/serum partition coefficients have wide ranges (42). This makes direct comparisons of contaminant concentrations in adipose and blood samples problematic, even when all concentrations are adjusted for lipids. Common blood lipid determinations are either gravimetric (where lipids are chemically separated from blood and weighed) or enzymatic (where measurements of cholesterol, triglycerides, and, often, phospholipids are used to estimate total lipids in blood; 43, 44). Several studies have examined correlations between concentrations of organochlorine chemicals in adipose and in serum, plasma, or whole blood, with little consensus (42, 4548). Besides physiological mechanisms, analytical error often adds to the discrepancy between measurements in adipose and in blood. This is particularly true when concentrations in small volumes of blood approach the limit of detection (47). Less variation may be expected in the distributions of lipophilic chemicals among various types of adipose tissues, but there are extremely few data in the literature. Current knowledge is hampered by the limited number of patients with measurements in more than a single tissue and by low body burdens that stretch analytical methodologies (45, 47) and increase analytical error.
In a related report, we presented the first systematically collected data on persistent halogenated contaminants from California (49). These chemicals were measured in breast adipose tissues of women participating in a breast cancer case-control study centered in the San Francisco Bay Area.5 In this article, we examine the distributions of persistent chemical contaminants in breast and abdominal adipose tissues in a subset of these women who underwent mastectomies with concurrent breast reconstruction. The current analysis is designed to provide insight into a serious methodological restriction involving the selection of appropriate controls in epidemiologic studies. Adipose is the tissue of choice for assessing steady-state body burdens of lipophilic contaminants, but invasive techniques are required for sample collection. Use of breast adipose samples to assess body burdens in breast cancer studies limits the eligible pool of controls to subjects who were prompted to undergo a biopsy following some abnormal finding in their breasts and whose biopsies were benign. The selection of these women for use as controls may be problematic in that benign breast conditions may actually be a risk factor for breast cancer. Conversely, selecting control subjects among women undergoing plastic surgery for breast implants or breast reduction may introduce bias in terms of age, socioeconomic status, etc. Use of abdominal adipose would help avoid the concern that use of benign breast biopsy controls may result in overmatching. In addition, if concentrations are equivalent, use of more easily accessible abdominal adipose tissue samples will allow future studies to draw from a wider selection of subjects. Furthermore, it would be possible to compare results across studies that had used different adipose tissues. Unfortunately, aside from case reports on few individuals (5053), no systematic effort has been reported on distributions of persistent organic chemicals in various types of adipose tissues. There is clearly a great need for a systematic study on this topic. We examined concentrations of major OCPs, PCBs, PCDDs/PCDFs, and PBDEs in breast and abdominal adipose tissues in an effort to address the question of contaminant distributions in different adipose stores. In addition, we report the great variation in lipid content of surgical specimens we observed.
| Materials and Methods |
|---|
|
|
|---|
Histopathology
The Department of Pathology at Stanford University and the Kaiser Permanente Hospital evaluated histologic sections of all breast lesions and coded diagnoses as invasive malignant disease, noninvasive malignant disease, ductal carcinoma in situ (DCIS), or benign histologic changes. For the purpose of this study, all 21 women undergoing the TRAM procedure were pooled irrespective of disease status (malignant, benign, or DCIS).
Sample Analysis
Samples were stored at -20°C until analysis. Samples were thawed, weighed, mixed with Na2SO4, homogenized with dichloromethane/hexane (1:1, v/v), and fortified with 13C-labeled internal standards [all 17 2,3,7,8-substituted PCDDs/PCDFs; PCBs 77, 126, 169, 28, 52, 47, 101, 105, 118, 153, 180, 194, and 209; hexachlorobenzene (HCB); ß-hexachlorocyclohexane (ß-HCH); DDE; DDT; dieldrin; mirex; and 3,3',4,4'-tetrabrominated diphenyl ether]. One-tenth of the extract was analyzed for OCPs, PCBs, and PBDEs and nine-tenths was analyzed for PCDDs/PCDFs and coplanar PCBs. Lipid content was determined in an aliquot of the extract by evaporating the solvent and weighing the remaining solids to constant weight (gravimetric determination). The extracted samples were serially processed through glass columns containing Na2SO4 and AX21 carbon. The first fraction off the carbon column was further cleaned up by gel permeation chromatography (Fluid Management Systems, Waltham, MA) and Florisil chromatography; recovery standards were added and the final extract was concentrated to 10 µl for PCB, OCP, and PBDE analysis (7). PCDDs/PCDFs and coplanar PCBs were eluted from the carbon column with toluene and the eluate was cleaned up through alumina and acid silica columns; recovery standards were added and the extract was concentrated to 10 µl.
PCDDs/PCDFs and PCBs were analyzed by high-resolution gas chromatography coupled with high-resolution mass spectrometry (Finnigan MAT90; Finnigan Corp., San Jose, CA) with a DB5ms (Agilent Technologies, Wilmington, DE) column (60 m, 0.25 mm ID, 0.25 µm film thickness). Perfluorokerosene was used to establish the lock masses and selected ions characteristic of the analytes were monitored. OCPs and PBDEs were analyzed by low-resolution mass spectrometry in negative chemical ionization mode (Finnigan 4510; Finnigan) with a DB5ms (Agilent Technologies) column (60 m, 0.25 mm ID, 0.25 µm film thickness). Methane was used as the reagent gas; the ion source pressure was 0.6 Torr and the ion source temperature was 100°C. The electron energy was typically 70 eV and the electron current was kept at 0.3 mA.
In addition to the individual 2,3,7,8-substituted PCDD/PCDF congeners, their International Toxic Equivalents (I-TEQ; the sum of 17 toxic congeners weighed by individual toxicity factors) were calculated using the I-TEQ convention (54). Toxicity factors decrease with increasing number of chlorines; therefore, tetra- and penta-substituted congeners drive the I-TEQ. The sum of the five prevalent PBDE congeners (total PBDE) is often used as a summary index of PBDE body burden.
Quality Assurance
Samples were analyzed in batches of six, and both abdominal and breast adipose samples from a TRAM study patient were included in the same batch. The identity and disease classification of the samples were masked. In addition to the six samples, each batch contained a reagent blank. Duplicate analyses were performed and standard reference materials (SRM 1945, whale blubber; National Institute of Standards and Technology, Gaithersburg, MD) were incorporated in the analysis.
Data Tracking
All completed questionnaires, medical records, and pathology reports were kept in a secure filing cabinet. Questionnaire information was extracted, coded, and entered in a computerized database (55) with the patient's medical record number as the sole identifier. Chemical analysis results were compiled in spreadsheets. Questionnaire data and chemical analysis data were merged and subjected to statistical analysis using SAS (56).
Statistical Methods
Duplicate analysis is a basic procedure to assess the precision of a chemical method and relative percentage differences (RPDs) are routinely used to assess agreement between duplicate chemical analyses. The RPD is defined as the ratio of the absolute value of the difference between two measurements over the average of the two measurements. The Mann-Whitney-Wilcoxon test was used to compare RPDs for a given chemical from the TRAM pairs to RPDs from duplicate analyses of breast adipose tissues to assess whether differences between tissues exceeded differences within the same tissue (analytical error).
The first question we wanted to address with these data was: Are concentrations in abdominal and breast adipose tissues the same? This question is addressed quantitatively with the intraclass correlation, a measure of concordance corrected for chance agreement (57). In a plot of the pairs of points, with the breast tissue value on one axis and the abdominal tissue values on the other, the intraclass correlation measures the scatter of the data around the 45° line of perfect agreement; intraclass correlation = 1 indicates perfect agreement. Agreement may also be tested with the Wilcoxon matched-pairs test, a nonparametric equivalent of the matched-pairs t test (57). In this case, the null hypothesis is that the (lipid-adjusted) concentration of an analyte in breast adipose is equal to its (lipid-adjusted) concentration in abdominal adipose.
If concentrations are not equal, a second question may be addressed: Even if the data are not interchangeable, can they still be used to derive one from the other? This is assessed by regression analysis and by examining the resulting R2 statistic, representing the amount of variance explained in one measure by accounting for the other. If the agreement between the two values is good, the R2 will be close to the square of the intraclass correlation coefficient. However, even in situations of poor absolute agreement, the R2 may be high if the data are well correlated. In that case, breast adipose concentrations could be derived from abdominal adipose concentrations using the regression equation.
| Results |
|---|
|
|
|---|
|
|
|
|
| Discussion |
|---|
|
|
|---|
In our study, with some notable exceptions, we could not detect significant differences between concentrations in abdominal and breast adipose tissues, and high intraclass correlation coefficients indicated good agreement in the measurements. Exceptions were observed with certain dioxin congeners. Both 2378-TCDD and 12378-PeCDD had low intraclass correlation coefficients (0.471 and 0.426, respectively), poor R2 (0.238 and 0.275, respectively), and slopes quite different from 1 (0.448 and 0.674, respectively), indicating preferential deposition of these chemicals in abdominal adipose tissue. In addition, the intercept for 2378-TCDD was statistically different from zero.
The hypothesis that concentrations were equivalent in the two types of tissues was rejected for 12378-PeCDD and barely accepted for 2378-TCDD at the 5% significance level. The summary index of dioxin exposure (I-TEQ), a weighed sum of the 17 most toxic PCDD/PCDF congeners, which is driven greatly by these two dioxin members, was also affected. Although analytical error was high as the measurements were near the detection limit for these two analytes, we cannot discount the possibility that these two tetra- and penta-chlorinated congeners (and possibly other similar molecules) partition differently than the more chlorinated and, therefore, bulkier congeners. The implication for breast cancer may be lower concentrations of 2378-TCDD and 12378-PeCDD in breast tissues and, possibly, less opportunity for toxicity. The hypothesis that concentrations are equivalent in the two types of tissues could not be rejected for any of the remaining target chemicals. In other words, given the uncertainty of the analytical method, the interindividual variability, the magnitude of the difference in concentrations in the two tissues, and the number of paired samples examined, no statistically significant differences could be detected. However, there may be real differences that our study did not have the power to detect. We did observe low R2 and deviations from a slope of 1 in the regression measurements for trans-nonachlor and oxychlordane. Whereas these two chemicals, both metabolites of chlordane, may indeed behave in a different way than other OCPs, the observed deviations are probably due to increased analytical error. This explanation is supported by the relatively high mean RPD for duplicate analysis for these two chemicals. Relatively poor fit (R2 = 0.41) was also observed for 2,2',4,4',5,6'-hexabrominated diphenyl ether (PBDE-154), a minor PBDE constituent. Interestingly, PBDE-154 had the lowest RPD of all PBDEs in the duplicate analyses and the highest RPD in the TRAM analyses with an almost statistically significant difference in RPDs (P = 0.06). In addition, the regression slope for this congener (0.56) indicates that it appears to partition more in the abdominal than in the breast adipose. Both PBDE-154 and 2,2',4,4',5,5'-hexabrominated diphenyl ether (PBDE-153), which are hexabrominated congeners and, hence, bulkier than the tetra- and penta-PBDE congeners, have similar slopes, perhaps reflecting steric hindrance in transport through membranes. The other (tetra- and pentabrominated) PBDE congeners and the total PBDEs (arithmetic sum of the five individual constituents), however, showed good fit and the latter was not affected by the erratic PBDE-154.
In summary, this analysis indicates that, with some interesting exceptions, measurements of many contaminants in abdominal and breast adipose tissues are highly correlated and that concentrations measured in one type of tissue could be used to estimate the concentration in the other tissue. The poor correlations we observed with the 2378-TCDD and 12378-PeCDD congeners, as well as with PBDE-154 and the two chlordane metabolites, may detract from the conclusion that concentrations in one type of tissue can predict concentrations in another type of tissue and, therefore, require further study. It is, however, reasonable to conclude that both abdominal and breast adipose tissues could be used to measure concentrations of many persistent lipophilic contaminants, greatly facilitating future epidemiologic studies. Additional work to validate these findings and, perhaps, predict partitioning based on structure-activity relationships of many lipophilic contaminants would guide the selection of appropriate biomonitoring plans in future studies.
These findings suggest that epidemiologic studies may be able to substitute measurements on one tissue for another, but we caution that the implications of such a decision be considered. Over half the compounds listed in Table 3 had intraclass correlations
0.9, but any correlation <1 will attenuate or reduce an observed relative risk estimate compared with a perfect measurement. For example, an intraclass correlation of 0.9 for a surrogate measurement can reduce a true odds ratio (OR) of 2.0 to an observed OR of 1.751.9 depending on how the OR is defined (quantiles, continuous measurement, etc.; 59). This will have the effect of reducing the study's statistical power. Conversely, to achieve the same power, the study's sample size would have to be increased by 23% (59). In addition, we note that the specific correlation values we report are dependent on the ranges of the concentrations obtained, and their applicability to other studies will require similar ranges. The concentration ranges (Table 2), however, are representative of those expected in contemporary U.S. populations9 (8, 60).
An important finding of our study was the high variability in lipid content observed in the adipose specimens. This variability may be explained by breast tissue anatomy, where adipose is interspersed within nonfatty connective tissue. It may also reflect differential presence of blood or other nonlipid components in the sample submitted for analysis. Given the small size of these samples (often <1 g), these nonlipid components may contribute to the weight of the specimen but not to the extractable lipids. If the actual lipid content of the specimen is not measured and contaminant concentrations are expressed on the basis of the total weight of the specimen, measurements in many patients will be underestimated. We should note that, given the miniscule size of the specimens and following common practice, we did not attempt to characterize the composition of lipids.
Figure 1 shows the percentage of lipid content of all the breast adipose specimens (N = 161) in our full study as a function of age. As shown in Fig. 1, younger women had a broader range of lipid content. Given that age is a known risk factor for breast cancer, use of non-lipid-adjusted adipose tissue concentrations may lead to misclassifications and distort the ORs for disease. Table 4 summarizes the major studies examining organochlorine contaminants as risk factors for breast cancer, the type of sample used (adipose, serum, and plasma), the analytes, if any, which were associated with breast cancer, and whether lipid adjustment was performed. It should be noted that some of these studies (21, 22) did not use lipid-adjusted adipose measurements, which may partially explain the contradictory findings. We firmly believe that tissue concentrations must be adjusted for lipid content to make valid comparisons from subject to subject within a study or to compare different studies.
|
| Acknowledgments |
|---|
| Footnotes |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. This article must therefore be hereby marked advertisement in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
Note: The ideas and opinions expressed herein are those of the authors and do not necessarily reflect the official position of the California Department of Toxic Substances Control or the California Department of Health Services.
5 Reynolds et al., unpublished observations. ![]()
6 Reynolds et al., unpublished observations. ![]()
7 Reynolds et al., unpublished observations. ![]()
8 Petreas et al., unpublished observations. ![]()
9 Petreas et al., unpublished observations. ![]()
Received 8/19/03; revised 10/20/03; accepted 11/ 4/03.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
J. A. Rusiecki, A. Matthews, S. Sturgeon, R. Sinha, E. Pellizzari, T. Zheng, and D. Baris A Correlation Study of Organochlorine Levels in Serum, Breast Adipose Tissue, and Gluteal Adipose Tissue among Breast Cancer Cases in India Cancer Epidemiol. Biomarkers Prev., May 1, 2005; 14(5): 1113 - 1124. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Cancer Research | Clinical Cancer Research |
| Cancer Epidemiology Biomarkers & Prevention | Molecular Cancer Therapeutics |
| Molecular Cancer Research | Cancer Prevention Research |
| Cancer Prevention Journals Portal | Cancer Reviews Online |
| Annual Meeting Education Book | Cell Growth & Differentiation |